This is the whole setup on a single page. If anything is unfamiliar, follow the linked page instead — each one explains the reasoning behind the step.

1. Wire it up

Your sensorConnection
E / M seriesPoE switch → cable → sensor
A / C seriesPoE switch → cable → PoE splitter → sensor

One cable carries both power and data. Details in Topology & power.

2. Match the host network

Put your computer’s Ethernet adapter on the same subnet as the sensor before you try to discover it. A different subnet means the sensor will not appear in the software at all. See Network.

3. Find the sensor

Open your point cloud software and scan the network.

SeriesSoftware
E seriesMagicViewer
A seriesMagicViewer
C seriesMagicViewer Classic
M seriesConfiguration Tool

See Find sensor.

4. Confirm the point cloud

A stable, correctly oriented cloud means the optics are clear and the scan is running. Fix the hardware before you change any configuration.

5. Change the IP

Set the sensor address for the customer’s network, then move your own adapter to the same subnet and verify with ping. See Set IP.

6. Calibrate

Run LiDARMagic Calibration. It is the same software for every series. See Calibration.

7. Test the interaction

Walk the detection area, check the edges, confirm the response latency. See Interaction test.

Common detours

SymptomLikely cause
Sensor never appears in the softwareHost adapter on a different subnet
Worked before the IP change, not afterHost adapter still on the old subnet
Point cloud appears, then stopsPower supply cannot deliver peak current during spin-up

Full list in Troubleshooting.