The Short Path
All eight steps on one page, for people who already know what they are doing.
This is the whole setup on a single page. If anything is unfamiliar, follow the linked page instead — each one explains the reasoning behind the step.
1. Wire it up
| Your sensor | Connection |
|---|---|
| E / M series | PoE switch → cable → sensor |
| A / C series | PoE switch → cable → PoE splitter → sensor |
One cable carries both power and data. Details in Topology & power.
2. Match the host network
Put your computer’s Ethernet adapter on the same subnet as the sensor before you try to discover it. A different subnet means the sensor will not appear in the software at all. See Network.
3. Find the sensor
Open your point cloud software and scan the network.
| Series | Software |
|---|---|
| E series | MagicViewer |
| A series | MagicViewer |
| C series | MagicViewer Classic |
| M series | Configuration Tool |
See Find sensor.
4. Confirm the point cloud
A stable, correctly oriented cloud means the optics are clear and the scan is running. Fix the hardware before you change any configuration.
5. Change the IP
Set the sensor address for the customer’s network, then move your own adapter to
the same subnet and verify with ping. See Set IP.
6. Calibrate
Run LiDARMagic Calibration. It is the same software for every series. See Calibration.
7. Test the interaction
Walk the detection area, check the edges, confirm the response latency. See Interaction test.
Common detours
| Symptom | Likely cause |
|---|---|
| Sensor never appears in the software | Host adapter on a different subnet |
| Worked before the IP change, not after | Host adapter still on the old subnet |
| Point cloud appears, then stops | Power supply cannot deliver peak current during spin-up |
Full list in Troubleshooting.