On this page
settings_ethernet
Set the IP Address
Three steps, in order: align the host, change the sensor, re-align the host and verify.
Changing a sensor’s address is three operations, not one. Skipping the third is the most common reason a sensor “disappears” right after being configured.
① host → sensor's current subnet
② change the sensor's IP ← the only software-specific part
③ host → sensor's new subnet, then verify with ping
① Align the host first
If you cannot reach the sensor, you cannot configure it. Set your adapter to a free address on the sensor’s current subnet — usually the factory one. The procedure is in Network & host setup.
Confirm before continuing:
ping -c 3 <sensor-current-ip>
② Change the sensor address
Write down the new address before you apply it. After the reboot the sensor is
unreachable from the old subnet, and the software will not find it again until
your adapter moves.
③ Re-align the host and verify
Move your adapter to the new subnet, then confirm:
ping -c 3 <sensor-new-ip>
If ping fails, check in this order:
| Check | Fix |
|---|---|
| Adapter still on the old subnet | Move it — this is the usual cause |
| Address already in use | Pick another; see IP conflict |
| Wrong subnet mask | Mask must match the sensor’s exactly |
| Sensor still rebooting | Wait 30 s and retry |
Record the assignment
Add the sensor to your installation’s address table: sensor serial, address, physical location. Service visits years later depend on it.
Next
Address set and reachable? Move on to Calibration.