LiDARMagic Calibration is the same application for A, C, E and M series — the series only affects which connection profile you select. Current release is 2.0.40, which also covers the Hokuyo UST family.

What calibration actually does

The sensor measures ranges along known angles, but the physical mounting decides how those angles map onto the surface you are making interactive. Calibration records that relationship: which part of the scan corresponds to which part of the projection or display.

Skip it and the interaction will track, but the touch points will be offset — usually by more at the edges than in the centre.

Prepare

ItemWhy
Sensor mounted in its final positionCalibration is position-specific; moving it invalidates the result
Projector or display runningYou calibrate against what the audience sees
Sensor on a reachable addressSee Set IP
Stable point cloudSee First point cloud
A clear, level surface for the reference targetsMeasurement error here propagates

Procedure

  1. Connect — open LiDARMagic Calibration, select the sensor, choose your series’ connection profile.
  2. Choose the geometry — flat wall, floor, table or curved surface. This decides the reference model used for fitting.
  3. Set the reference points — follow the on-screen prompts; place the targets where the software asks, not where they are convenient.
  4. Run the fit — the software reports a residual. A value that keeps growing after several iterations means a bad reference point, not a bad sensor.
  5. Save the profile — write it to the sensor or to the project file, depending on your workflow. Record which profile belongs to which installation.

Verify

CheckPass condition
ResidualStays flat across iterations
Corner accuracyTargets at the edges of the active area respond where touched
RepeatabilityWalking the same path twice produces the same trace
After power cycleCalibration persists

If the residual improves but corner accuracy does not, the geometry selection is usually wrong — a curved surface modelled as flat fits the centre and fails the edges.

Next

Calibrated? Test the actual interaction: Interaction test.