On this page
cloud_off
No Point Cloud
The sensor is found but the cloud is missing, empty, or stops after a few seconds.
Separate the two cases
| Case | Meaning | Where to look |
|---|---|---|
| Never appeared | Device listed but no data at all | Software configuration, protocol |
| Appeared then stopped | It ran, so power and data were fine once | Power budget, thermal, cable |
The second case is far more common in the field and is almost always power.
Runs a few seconds, then stops
The spin-up peak draws two to three times the steady-state current. A supply that is adequate at idle can still brown out during acceleration.
| Check | Pass condition |
|---|---|
| Supply rating vs datasheet peak | Headroom of at least 30% |
| PoE port budget | Not already loaded by other devices |
| Cable gauge over the run | Sized for peak, not average |
| Splitter rating (A / C) | ≥ peak current at 12 V |
Never appeared
| Check | Why |
|---|---|
| Device status in the software | “Found but idle” is a different fault from “streaming but blank” |
| Host firewall blocking UDP | A local firewall silently drops the stream |
| Wrong network adapter selected | VPN and Wi-Fi adapters |
| Software version | Older builds may not support newer firmware |
Cloud renders but is empty
A few points at zero distance usually means the window is covered or the sensor is mounted against a surface. Check the optical path before the electronics.
Next
If the device is not even listed: Cannot find sensor.