Power, Network and Cabling
Connector pinouts, voltage tolerance and cabling standards for permanent installations.
Power requirements
| Parameter | Value | Notes |
|---|---|---|
| Input voltage | 12 V DC nominal | Confirm the range for your specific model |
| Peak current | See datasheet | Occurs during spin-up, not at steady state |
| Connector | Per model | M12 industrial or flying leads depending on variant |
The sensor contains a spinning optical assembly. Supply impedance matters: a long, thin cable that works at idle can cause brown-out during spin-up. Size the conductor for peak current, not average.
Network
The sensor exposes data over UDP. Keep it on an isolated segment or a dedicated VLAN — broadcast traffic from a busy office network will cause packet loss that looks like a sensor fault.
Cabling standards
For permanent installations:
- Terminate the shield at one end only, at the host side.
- Keep the power pair twisted and separated from the data pair.
- Use a strain relief that grips the jacket, not the conductors.
Do not hot-plug the power connector. The inrush path has no soft-start on
standard variants, and repeated hot-plugging degrades the connector.